At a glance
- Configuration
- Enclosed station
- Voltage / Frequency
- 380 V / 3-phase / 50 Hz (standard)
Model range
SE-050 is one model within the StationPack SE enclosed-station family at a larger flow step than SE-020.
Configuration
Enclosed station
- Configuration
- Enclosed station
Installation
Installation
- Outdoor, noisy, dusty or temporary sites at higher flow
How To Choose
By site conditions
- START WITH
- Required flow and pressure
- THEN CHECK
- Ambient, altitude, dust, noise limit
- BEFORE A QUOTE
- Confirm the model row with SIND
Technology
Technology Platform
SE-050 uses the StationPack SE enclosed-station platform at a larger flow step than SE-020. Multiple compression elements, treatment train, storage volume, common control and common cooling-air circuit in one weatherproof enclosure. The enclosure panels keep weather out and sound in, but also keep heat in — so intake and hot-air escape are designed as one thermal circuit.
Why Enclosed Station?
Enclosed station applies where the installation environment is unsheltered or demanding:
Key Design Decision: Thermal Circuit
The enclosure is part of the thermal design. Intake air must enter the enclosure in a controlled path, absorb heat from the compression and treatment equipment, and escape without recirculation. Poor thermal design raises internal ambient, reduces compressor delivery and shortens element life. SE stations are designed with intake louvres, internal baffles and exhaust louvres as one circuit.
More technical detail
Why Enclosed Station?
- Outdoor installation — no plant room required; the enclosure provides weather protection.
- Noise-sensitive boundary — the enclosure attenuates sound, reducing the need for a separate compressor room.
- Dusty or salty environment — the enclosure protects internal components from ingress.
- Temporary or relocatable duty — the station can be moved as the site evolves.
Integration and Control
The station arrives as one item with one set of test records. One control system sequences the machines and holds one narrow pressure band at the header, instead of each machine hunting on its own switch. The treatment train is sized against what the compressor delivers at the site’s pressure and ambient, not against a nameplate peak flow.
Selection & quote checklist
- Outdoor installation — No plant room available
- Higher flow requirement — Larger flow than SE-020
- Noise-sensitive boundary — Enclosure attenuation required
- the exact model and configuration
- required operating pressure and flow
- electrical supply (voltage, frequency, phase)
Applications
Outdoor Mining Site
A mining site requires compressed air at higher flow but has no plant room.
Noise-Sensitive Urban Site
An urban manufacturing site is near a residential area with noise limits and requires higher flow.
Coastal Installation
A coastal installation requires compressed air in a salty environment. SE-050’s enclosed configuration protects internal components from salt ingress, extending equipment life.
Ownership & service
Energy, maintenance and service
Target Industries and Markets
SE-050 is specified where an enclosed compressor station is required at higher flow:
- Outdoor sites — construction, mining, temporary installations with no plant room.
- Noise-sensitive locations — urban sites, sites near residential areas.
- Dusty or salty environments — quarries, coastal installations, desert sites.
- Temporary or relocatable duty — rental fleets, sites that move.
How This Compares with Site-Assembled Stations
The point of StationPack SE is the boundary. Everything a buyer would otherwise assemble on site arrives as one item with one set of test records. One control system sequences the machines and holds one narrow pressure band at the header. The treatment train is sized against what the compressor delivers at the site’s pressure and ambient, not against a nameplate peak flow. The enclosure is part of the thermal design, not an afterthought.
Specifications vary by configuration; confirm with the datasheet. Dimensions and weights are indicative; request the installation drawing for the specific model before designing foundations or access routes.
Reference data
Full specification and reference tables
- Outdoor installation — No plant room available
- Higher flow requirement — Larger flow than SE-020
- Noise-sensitive boundary — Enclosure attenuation required
- the exact model and configuration
- required operating pressure and flow
- electrical supply (voltage, frequency, phase)
- the current datasheet and package contents
-
SE-020 or SE-050?
Both are enclosed stations. SE-050 provides higher flow than SE-020. Confirm the flow step with SIND against your actual duty.
-
SE-050 or SN (open skid)?
SE-050 enclosed for outdoor, noisy or dusty environments. SN open skid for a sheltered plant room with existing ventilation and access.
-
What is inside?
Compressor(s), drive(s), cooling, aftercooler, separator and drain, storage volume, drying and filtration, control and protection, weatherproof enclosure, internal pipework and wiring. Exact scope is confirmed per order.
-
Is 60 Hz available?
50 Hz standard. 60 Hz configuration on request — confirm voltage, frequency and phase with your SIND representative before order.