StationPack SN-H Horizontal Integrated Screw Air Compressor Station

StationPack SN-H is an integrated compressor station for plant-room compressed-air supply, 50/60 Hz.

ModelStationPack SN-H Horizontal Integrated Screw Air Compressor Station
CategoryStationPack SN (2.2–55 kW)
Frequency50 Hz / 60 Hz — confirm per model
FinishGrey as standard — blue or custom colours available on request
SupportSpare parts & service support in Southeast Asia, South Asia, the Balkans and Russia

At a glance

Type
Integrated compressor station
Series
SN (open skid) / SE (enclosed)
Scope
Compressor, drive, receiver, dryer, filtration, control
Cooling
Air-cooled (A) or water-cooled (W)
Control
Station sequencer with pressure-band control
Delivery
One skid or enclosure, factory-tested
Overview

STATIONPACK is the SIND integrated compressor station family. Two series are planned: SN (small open all-in-one station on one skid) and SE (large enclosed station in a weatherproof enclosure). Everything a buyer would otherwise assemble on site arrives as one item with one set of test records — compressor, drive, receiver, dryer, filtration, condensate management and control, factory-piped and factory-tested.

Model range

STATIONPACK covers two series: SN (open skid) and SE (enclosed). Contact SIND for the current coverage.

SN-Series

Open skid station

Installation
Indoor, sheltered plant room

Access
Open — easy maintenance access

Best for
Existing plant rooms with ventilation

SE-Series

Enclosed station

Installation
Outdoor, noisy, dusty or salty

Enclosure
Weatherproof, sound-attenuated

Best for
Outdoor, temporary or relocatable

How to choose

By flow, pressure and air quality

Start with
Required FAD, pressure and air quality

Then check
Installation location and load profile

Before a quote
Confirm the model row with SIND

Technology

Technology Platform

StationPack is an integrated compressor station — not a single compressor, but a complete compressed air system on one skid or in one enclosure. The station includes:

SN vs SE: Open or Enclosed?

The choice between SN (open) and SE (enclosed) turns on one question: where will the station be installed?

Station Sequencer and Pressure-Band Control

The point of an integrated station is the boundary. Everything arrives as one item with one control system. The station sequencer sequences the compressors and holds one narrow pressure band at the header, instead of each machine hunting on its own switch.

More technical detail

Technology Platform

  • Compression — one or more compressors (screw, depending on the duty).
  • Drive — fixed-speed base load with variable-speed trim, or all variable-speed.
  • Cooling — aftercooler and lubricant cooler, air-cooled or water-cooled.
  • Separation and drainage — oil separator (if oil-injected) and condensate drains.
  • Storage — receiver tank for buffer volume and pressure stability.
  • Treatment — dryer (refrigerated or desiccant) and filtration (coalescing, particulate, carbon as required).
  • Control — station sequencer with pressure-band control, sequencing the compressors and holding one narrow pressure band at the header.
  • Enclosure or baseframe — open skid (SN) or weatherproof enclosure (SE).
  • Internal pipework and wiring — factory-piped and factory-tested.

SN vs SE: Open or Enclosed?

The split is functional, not arbitrary. SN is open for a sheltered plant room; SE is enclosed for outdoor, noisy or dusty environments.

  • SN (open skid) — for plant rooms with existing ventilation and access. The open skid allows free airflow for cooling and easy access for maintenance. SN is specified for indoor installations in sheltered plant rooms.
  • SE (enclosed) — for outdoor or semi-outdoor sites, noise-sensitive boundaries, dusty or salty environments, and temporary or relocatable duty. The weatherproof enclosure keeps weather out, sound in and heat in. The enclosure becomes part of the thermal design — the panels that keep weather out and sound in also keep heat in, so intake and hot-air escape must be designed as one circuit.

Station Sequencer and Pressure-Band Control

Lead/lag sequencing with equal-run-hour rotation ensures all compressors accumulate similar operating hours, balancing maintenance intervals. Fixed-speed base load with variable-speed trim provides efficient part-load performance — the fixed-speed machine runs at full load (most efficient point), and the variable-speed machine trims to match air demand.

Treatment Train Sizing

The treatment train (dryer and filters) is sized against what the compressor delivers at the site’s pressure and ambient, not against a nameplate peak flow. This ensures the dryer and filters are correctly sized for the actual duty, not oversize or undersize.

Dryer selection (refrigerated or desiccant) turns on the required pressure dew point. Filtration selection (coalescing, particulate, carbon) turns on the required air quality. Heat recovery is optional where a plant hot-water use exists.

Thermal Design

For enclosed stations (SE), the enclosure becomes part of the thermal design. The panels that keep weather out and sound in also keep heat in. Intake and hot-air escape must be designed as one circuit — cooling air enters through the intake louvre, passes over the coolers and motors, and exits through the hot-air escape louvre. The thermal design must account for design summer ambient, solar gain and the heat rejected by the compressors and coolers.

For open stations (SN), the plant room ventilation must provide sufficient cooling airflow. The station requires free airflow for cooling — obstructions, recirculation or inadequate ventilation cause high temperatures and shutdowns.

Selection Logic

StationPack selection is based on the following parameters:

  1. Required flow (m³/min): determined by the sum of all simultaneous air consumers plus margin.
  2. Required pressure (bar(g)): determined by the furthest endpoint’s minimum working pressure plus pipeline losses.
  3. Required air quality (pressure dew point, oil content, particulate): determines the treatment train.
  4. Installation location (indoor/outdoor, ambient, noise limit): determines SN or SE.
  5. Load profile (continuous, intermittent, part-load): determines the compressor arrangement (fixed-speed base load + variable-speed trim, or all variable-speed).

Selection & quote checklist

  1. Required flow (m³/min): determined by the sum of all simultaneous air consumers plus margin.
  2. Required pressure (bar(g)): determined by the furthest endpoint’s minimum working pressure plus pipeline losses.
  3. Required air quality (pressure dew point, oil content, particulate): determines the treatment train.
  4. Installation location (indoor/outdoor, ambient, noise limit): determines SN or SE.
  5. Load profile (continuous, intermittent, part-load): determines the compressor arrangement (fixed-speed base load + variable-speed trim, or…

Send this checklist with your RFQ →

FAQ

SN or SE?

SN for a workshop with its own plant room; SE outdoors or in a noisy bay.

What is inside?

Compressor, drive, cooling, aftercooler, separator and drain, storage volume, optional drying and filtration, control and protection, baseframe or enclosure, internal pipework and wiring. Exact scope is confirmed per order.

Installation?

Foundations, power, cooling air for enclosed packages, header and condensate connections. Drawings are available on request.

Maintenance and spares?

Airend service, oil circuit, dryer and filter elements, drains, cooler cleaning. Intervals and part numbers are available on request.

Is 60 Hz available?

50 Hz standard. 60 Hz configuration on request.

Ownership & service

Energy, maintenance and service

Target Industries and Markets

StationPack is specified where a complete, factory-tested compressed air system is required:

  • New workshops without a compressor room — one skid delivered, not eight loose components.
  • Adding capacity to existing plant headers — one station ties into the existing header.
  • Outdoor or noisy bays — enclosed station (SE) for outdoor or noise-sensitive locations.
  • Temporary sites and rental fleets — relocatable station on one skid.
  • Hot, dusty or high-altitude locations — station designed for the site conditions.
  • Process-critical and food-grade air systems — complete system with correct treatment train.

Energy and Total Cost of Ownership

The total cost of ownership for an integrated station turns on three items: purchase cost, energy cost and maintenance cost.

  • Purchase cost — an integrated station typically costs less than assembling the same components separately on site, because the station is engineered, piped and tested as one system.
  • Energy cost — the station sequencer holds one narrow pressure band at the header, reducing pressure fluctuations and energy waste. Fixed-speed base load with variable-speed trim provides efficient part-load performance. The treatment train is correctly sized for the actual duty, avoiding oversize (energy waste) or undersize (air quality failure).
  • Maintenance cost — one supplier, one set of maintenance records, one responsibility. Airend service, oil circuit, dryer and filter elements, drains, cooler cleaning — all from one source.

Specifications vary by configuration; confirm with the datasheet. Dimensions and weights are indicative; request the installation drawing for the specific model before designing foundations or access routes.

SIND technical advisor

Not sure which model fits?

The SIND technical advisor helps you match capacity and configuration to your actual operating conditions before you specify.

Sizing & selection notes

  • Match free air delivery to measured demand, with room for future production lines.
  • Set working pressure at the point of use, including pressure drop across filters and dryers.
  • Define the dryness and filtration you actually need, not the highest class by default.
  • Weigh lubricated against oil-free, and fixed against variable speed, for your load profile.
  • Allow for ambient temperature, altitude, ventilation and duty cycle, which cut usable capacity.